LVC07A DATASHEET PDF

  • June 13, 2019

LVC07A HEX Buffers/drivers WITH Open-drain Outputs. FEATURES. Operate From 5 V Inputs and Open-Drain Outputs Accept Voltages V. These hex. LVC07A Datasheet, LVC07A PDF, LVC07A Data sheet, LVC07A manual, LVC07A pdf, LVC07A, datenblatt, Electronics LVC07A, alldatasheet, free, datasheet. LVC07A datasheet, LVC07A circuit, LVC07A data sheet: TI – HEX BUFFERS DRIVERS WITH OPEN-DRAIN OUTPUTS,alldatasheet, datasheet, Datasheet.

Author: Doukinos Yogal
Country: Trinidad & Tobago
Language: English (Spanish)
Genre: History
Published (Last): 2 December 2016
Pages: 490
PDF File Size: 8.74 Mb
ePub File Size: 15.4 Mb
ISBN: 228-3-60816-518-7
Downloads: 5142
Price: Free* [*Free Regsitration Required]
Uploader: Baktilar

Good that you got something in writing. The note in the LVC07A datasheet “The output voltage ratings may be exceeded if the output current ratings are observed” allows you to let the output be pulled higher than the suggested limit of 6.

Sample As a Vlc07a customer you can order samples via our sales organization or directly via our Online Sample Store: Product details Documentation Support Ordering.

74LVC07APW – Hex buffer with open-drain outputs | Nexperia

Thank you Spehro, this is an excellent and thorough answer, and you provided an alternative solution that is elegant and economical. Your uA should be no issue in fact, you may want to reduce that 10K resistor if you need to improve the rise time of the output signal Regards Tom Logic Applications Engineering I find it interesting that he refers to the Absolute Maximum Rating as a “suggested limit.

The 74LVC07A provides six non-inverting buffers. Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. By using our site, you acknowledge that you have read and understand our Cookie PolicyPrivacy Policyand our Terms of Service. Spehro Pefhany k 4 This was the response:. It’s also better to drive the inputs right to the rails otherwise the current draw of the could go up.

Production processing does not necessarily include testing of all parameters.

  BURDA WYPLOSZ MAKROEKONOMIA PODRCZNIK EUROPEJSKI PDF

LVC07A Datasheet

Home – IC Supply – Link. Sample orders normally take days for delivery. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.

That’s what I suggest doing.

LVC07A 데이터시트(PDF) – TI store

I find “should be no issue” somewhat different from “is definitely no problem” though. Products conform to specifications per the terms of the Texas Instruments standard warranty. As a Nexperia customer you can order samples via our sales organization or directly via our Online Sample Store: The footnote says “The output voltage ratings may be exceeded if the output current ratings are observed.

Using the 74LVC07A is one of the more common ways to interface 3. Since I eventually received a reply to my inquiry from NXP Support, and they responded that my original approach was permissible, I have posted their response and I expect to mark it as the correct answer.

Find answers to your design questions on this page. Remember that “limiting values” aka “absolute adtasheet are not intended to indicate where the part should be operated continuously for reliable operation.

You’re kind of in a gray area. Inputs can be driven from either 3. Home Questions Tags Users Unanswered. At first glance, the current should always be well below the 50mA max output current spec, so I would expect this configuration to be fine.

Maybe someone on this forum can give me a definitive answer so I can lbc07a with the design.

The maximum sink current is 24 mA. Post Your Answer Discard By clicking “Post Your Answer”, you acknowledge that you have read our updated terms of serviceprivacy policy and cookie policy datashset, and that your continued use of the website is subject to these policies. This feature allows the use of. Ignore that at your peril- only you know what the consequences of a failure are.

  ALDWELL SCHACHTER HARMONY PDF

This feature allows the use of these devices as translators in mixed 3. Sign up or log in Sign up using Google. Support Find answers to your design dtaasheet on this page. The output should not break down until you get to more than 6. This was the response: By clicking “Post Your Answer”, you acknowledge that you have read our updated terms of serviceprivacy policy and cookie policyand that your continued use of the website is subject to these policies.

Post as a guest Name. Sign up using Facebook. The recommended maximum output voltage for normal operation is less than 5. Since this answer comes from the device manufacturer, I will mark it as being the correct answer. Products conform to specifications per the terms of the Texas. An MCU with 3. Features 5 V tolerant inputs and outputs open-drain for interfacing with 5 V logic Wide supply voltage range from 1.

Production processing does not. Email Required, but never shown. Your uA should be no issue in fact, you may want to reduce that 10K resistor if you need to improve the rise time of the output signal.

I sent this question to NXP tech support 3 days ago, and haven’t heard from them yet. Inputs can be driven from 1. Sign up using Datasbeet and Password. This feature allows the use of these devices as translators datasehet a mixed-system environment. Adtasheet Search Cross reference Parametric search.